How To Select The Monitored Signals; Index - ABB ACS550 User Manual

Hide thumbs Also See for ACS550:
Table of Contents

Advertisement

50

How to select the monitored signals

Step
Action
1.
You can select which signals are monitored in the Output mode and how they
are displayed with
detailed instructions on changing parameter values.
By default, the display shows three signals. The particular default signals
depend on the value of parameter
default value of parameter
default for signal 1 is
for signals 2 and 3 are always
To change the default signals, select up to three signals from
OPERATING DATA
Signal 1: Change the value of parameter
the signal parameter in
parameter without the leading zero), e.g. 105 means parameter
Value 100 means that no signal is displayed.
Repeat for signals 2
2.
Select how you want the signals to be displayed: as a decimal number or a bar
graph. For decimal numbers, you can specify the decimal point location, or use
the decimal point location and unit of the source signal [setting (9 (
details, see parameter 3404.
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
3.
Select the units to be displayed for the signals. This has no effect if parameter
3404/3411/3418
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
4.
Select the scalings for the signals by specifying the minimum and maximum
display values. This has no effect if parameter
(DIRECT). For details, see parameters
Signal 1: parameters
Signal 2: parameters
Signal 3: parameters
Control panels
Group 34: PANEL DISPLAY
9902
APPLIC MACRO
9904
MOTOR CTRL MODE
0102
, otherwise
SPEED
0104
CURRENT
to be shown.
3401
Group 01: OPERATING DATA
(3408
2
) and 3
SIGNAL
PARAM
3404
1
OUTPUT
DSP FORM
3411
2
OUTPUT
DSP FORM
3418
3
OUTPUT
DSP FORM
is set to 9 (
). For details, see parameter 3405.
DIRECT
3405
1
OUTPUT
UNIT
3412
2
OUTPUT
UNIT
3419
3
.
OUTPUT
UNIT
3406
3406
1
and
OUTPUT
MIN
3413
2
and
OUTPUT
MIN
3420
3
and
OUTPUT
MIN
parameters. See page
49
: For macros whose
is 1 (
:
), the
VECTOR
SPEED
0103
. The defaults
OUTPUT FREQ
and
0105
, respectively.
TORQUE
Group 01:
1
to the index of
SIGNAL
PARAM
(= number of the
0105
TORQUE
(3415
3
SIGNAL
PARAM
DIRECT
.
3404/3411/3418
is set to 9
and 3407.
3407
1
OUTPUT
MAX
3414
2
OUTPUT
MAX
3421
3
.
OUTPUT
MAX
ACS550 User's Manual
Display
LOC
PAR EDIT
for
3401 SIGNAL1 PARAM
OUTPUT FREQ
[103]
CANCEL
00:00
LOC
PAR EDIT
3408 SIGNAL2 PARAM
CURRENT
[104]
CANCEL
00:00
LOC
PAR EDIT
3415 SIGNAL3 PARAM
TORQUE
.
[105]
CANCEL
00:00
).
LOC
PAR EDIT
3404 OUTPUT1 DSP FORM
DIRECT
)]. For
[9]
CANCEL
00:00
LOC
PAR EDIT
3405 OUTPUT1 UNIT
Hz
[3]
CANCEL
00:00
LOC
PAR EDIT
3406 OUTPUT1 MIN
0.0 Hz
CANCEL
00:00
LOC
PAR EDIT
3407 OUTPUT1 MAX
500.0 Hz
CANCEL
00:00
SAVE
SAVE
SAVE
SAVE
SAVE
SAVE
SAVE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs550-01Acs550-u1

Table of Contents