Siemens Sinumerik 840C Diagnostics Manual page 114

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

1 Alarms
1.5.1 Alarm description
105042
Incorrect reference to dialog description for no. ...
Scan
Power up
Effect
Reference set to the first dialog description.
Explanation
Error during conversion of ASCII files. A message has a reference to a dialog description greater than or equal to
the number of dialog descriptions.
Remedy
Eliminate error in the alarm configuration
Note
SW 5 and higher
105043
Message no. ... neither dialog nor message
Scan
Power up
Effect
Value 0 understood.
Explanation
Error during conversion of ASCII files. The third from last parameter of the message description is not 0 or 1 (0 for
message line, 1 for dialog box)
Remedy
Eliminate error in the alarm configuration.
Note
SW 5 and higher
105044
Syntax error in message configuration
Scan
Power up
Effect
Binary files have been read from the Siemens branch.
Explanation
Error during conversion of ASCII files. The converter could not interpret the message attribute/message text files.
The binary files from the Siemens branch have been read in.
Remedy
Eliminate error in the alarm configuration.
Note
SW 5 and higher
105045
No communication to PLC
Scan
Permanently
Effect
MMC cannot communicate with PLC
Explanation
Communication with PLC aborted after an error or time overrun
Remedy
Check whether module is slotted in, notify Service.
105046
PLC failed with error ...
Scan
Permanently
Effect
If the PLC signals an error, the error number is entered in the alarm log
Explanation
Used for logging the PLC error number
Remedy
Report error no. to Siemens, log module
105047
PLC Reset – please wait ...
Scan
Permanently
Effect
No communication possible with PLC at the moment
Explanation
This alarm is displayed while communication is started, e.g. after a link bus reset. It dissappears after a short time
Remedy
Wait
105048
Text in ... not available
Scan
After Power On
Effect
A language which is not available has been set in the config file in the master control
Explanation
Siemens settings apply
Remedy
Set correct language and Power On
1–106
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
08/96
04/96
Acknowledgement key
Acknowledgement key
Acknowledgement key

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents