Siemens Sinumerik 840C Diagnostics Manual page 165

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

04/96
160087
Max. acceleration too small
Fine quantization too small
Coarse quantization too small
Number of learning runs too small
S
Scan
Reparameterization of the maximum acceleration (function parameter of the neural quadrant error compensa-
tion)
S
Reparameterization of the fine quantization (function parameter of the neural quadrant error compensation)
S
Reparameterization of the coarse quantization (function parameter of the neural quadrant error compensation)
S
Reparameterization of the number of learning runs (function parameter of the neural quadrant error compensa-
tion)
S
Effect
Start-up function aborts
S
Explanation
Input of maximum acceleration zero is not allowed.
S
Fine quantization must be greater than or equal to 4 and less than or equal to 32.
S
Coarse quantization must be greater than 1.
S
A number of learning runs less than 5 or greater than 40 is not allowed.
S
Remedy
Enter a larger value in the function parameter max. acceleration.
S
Enter a valid value in the fine quantization.
S
Enter a valid value in the coarse quantization.
S
Enter a valid value.
160088
Axis/spindle name ... invalid
Scan
DAC function parameterization
Effect
The function cannot be started
Explanation
The stated axis/spindle does not exist
Remedy
Correct input
160089
Axis/spindle number ... invalid
Scan
DAC function parameterization
Effect
The function cannot be started
Explanation
The stated axis/spindle does not exist
Remedy
Correct input
160090
Hard disk full, create file ...
Scan
Startup application file services
Effect
The data set in question is not stored
Explanation
Note enough memory on hard disk
Remedy
Remove file not required
160091
Data block of ... file invalid
Scan
Startup application file services (read only)
Effect
No data is read
Explanation
The contents of the selected file are not consistent
Remedy
None
160092
File ... not loaded completely
Scan
Startup application file services (read only)
Effect
The read data set is not complete
Explanation
Contents of file were not transferred completely
Remedy
Repeat procedure
Siemens AG 2001 All rights reserved 6FC5198–jAB40