Siemens Sinumerik 840C Diagnostics Manual page 191

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

04/96
07/97
300001
Configuration error drive number
Scan
When 611D drive link is being established
Effect
611D link is not established
Explanation
Illegal drive number entered
Remedy
Enter a drive number between 1 and 15
Note
Applies as from SW 3
300002
Configuration error module type
Scan
Establishing the 611D drive link
Effect
611D link not established
Explanation
The configured module type does not correspond to the actual module type
Remedy
Correct 611D module type (1/2 axis module)
Note
Applies as from SW 3
300003
Configuration error bus configuration
Scan
Establishing the 611D drive link
Effect
611D link not established
Explanation
The configured bus configuration does not correspond to the actual bus configuration (more actual drives as
configured)
Remedy
Correct 611D configuration; check hardware
Note
Applies as from SW 3
300004
Configuration error meas. cct. components
Scan
Establishing the 611D drive link
Effect
611D link not established
Explanation
Measuring circuit modules wrongly assigned (submodules missing or incorrect submodule type) or faulty
Remedy
Replace drive module
Note
Applies as from SW 3
300005
Configuration error drive type
Scan
Extablishing the 611D drive link
Effect
611D link not established
Explanation
The configured drive type (FDD/MSD) does not correspond to the actual
drive type
Remedy
Correct configuration or replace modules
Note
Applies as from SW 3
300006
CRC error drive link
Scan
Cyclic
Effect
Machining stops, interlocking of NC START and Mode Group Ready
Explanation
Interference on 611D drive link
Remedy
Check control cabinet wiring; consult EMC regulations
Note
Applies as from SW 3
As from SW 6, the alarm 300006 "CRC error drive link" is displayed only by the drive on which read access could
not be executed. In addition, both error registers from the DCM are displayed for further information on the alarm. If
the information from the error registers is not sufficient to determine a drive number, the alarm is output for the first
drive available.
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
POWER ON
POWER ON
POWER ON
POWER ON
POWER ON
POWER ON
1–183

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents