04/96
110010
Workpiece archiving in punch tape format only
Scan
DATA IN-OUT / DATA OUTPUT / WORKPIECES
Effect
–
Explanation
A workpiece or job list can only be archived in punch tape format
Remedy
Select punch tape format via toggle field
110011
There is no error log
Scan
Error log
Effect
None
Explanation
No error log was created for the previous data transfer
Remedy
–
110012
Selected data cannot be printed
Scan
DATA IN-OUT / PRINT
Effect
–
Explanation
Selected data cannot be printed
Remedy
Select data (e.g. MPF ..) which can be printed
110013
There is no job list for printer
Scan
DATA IN-OUT / PRINT / JOB LIST
Effect
–
Explanation
The printer has no job to process at the moment
Remedy
–
110015
Floppy was not formatted
Scan
DATA IN-OUT / FORMAT / OK
Effect
Diskette not formatted
Explanation
General error during formatting
Remedy
Check disk drive/cable
110016
Floppy is write-protected
Scan
DATA IN-OUT / DATA OUTPUT / ... / START
(INSERT NEXT DISKETTE)OK
DATA IN-OUT / FORMAT / OK
Effect
Data are not stored or diskette is not formatted
Explanation
The diskette tab is in the wrong position
Remedy
Remove write-protection or insert another diskette
110017
No floppy inserted
Scan
DATA IN-OUT / DATA OUTPUT / ... / START
DATA IN-OUT / DATA INPUT / START
(INSERT NEXT DISKETTE)
OK DATA IN-OUT / FORMAT / OK
Effect
–
Explanation
There is no diskette in the floppy disk drive
Remedy
Insert diskette
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey