04/96
01/99
300862
Emergency retraction/generator active
Note
Alarm description see 300762
300863
Generator/emergency retraction mode invalid
Note
Alarm description see 300763
300864
No emergency retraction/generator mode possible
Note
Alarm description see 300764
300865
No link measurement possible
Note
Alarm description see 300765
300875
Fixed voltage axially unequal
Note
Alarm description see 300775
300888
Parameterization error current controller adaptation
Note
Alarm description see 300788
300899
Save and boot necessary
Note
Alarm description see 300799
300900
Stop A triggered
Scan
In monitoring cycle.
Effect
The drive is stopped with STOP A.
Pulses are disabled via relay "Drive_IMP".
Motor runs down
Power on error
Explanation
There can be several reasons for triggering STOP A:
S
The time frame in MD 1356 of STOP B has expired.
S
The speed has fallen below the threshold in MD 1360 of STOP B.
S
The shut–down path test has been requested by the user by SGE "test stop selection", but the pulses were
not deleted after expiry of the time frame in MD 1357.
Remedy
The user must find the cause and initiate appropriate measures.
Note
Applies as from SW 5.4
300901
Stop B triggered
Scan
Cyclic in SI monitoring cycle.
Effect
The drive is stopped with STOP B. The pulses are then disabled via relay "Drive_IMP".
Explanation
There can be several reasons for triggering STOP B:
S
The safe standstill monitoring has responded.
S
STOP B was requested after STOP F, i.e. an error has occurred during cross–comparison.
Remedy
The user must find the cause and initiate appropriate measures.
Note
Applies as from SW 5.4
300906
Safe braking ramp exceeded
Scan
Cyclic in SI monitoring cycle.
Effect
The drive is stopped with STOP A. The pulses are then disabled via relay "Drive_IMP".
Explanation
Die Istgeschwindigkeit der Achse ist beim Bremsen mit "nsoll=0" (Stop B oder Stop C) nicht verringert worden,
sondern ist über die beim Bremsen nachgeführte Geschwindigkeitsgrenze und die in MMMMD_SB_STOP_N_TOL
(Toleranz Istgeschwindigkeit für SBR) eingetragene Toleranz angestiegen.
Remedy
Eingabewert des Maschinendatums MD_SB_STOP_N_TOL überprüfen.
Note
Applies as from SW 6
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
POWER ON
POWER ON
POWER ON