2 Diagnostics on the PLC
2.1 Error numbers (ACCU 3 high byte, DB 1 DW 160)
Operational and
user errors
70
Check sum error in RAM for OB, FB, DB, FX, SB, PB *)
71
Check sum error in EPROM for OB, FB, DB, FX, SB, PB *)
72
RAM error in user data memory
73
RAM error in system data memory
74
NC (master) CPU in the system failed
75
PLC CPU in the system failed
76
Reserved for 840
77
Reserved
W 78
PLC STOP by request from programmer
W 79
PLC STOP by operating mode switch
W 7A
Reserved for 840
W 7C
No ready signal from interface DMP or interface PLC or 135 WD
S
Interface may be blocked
S
Connector missing
Error messages from
interrupt routines
80
Division error
81
Overflow error
82
"Array Bounds" error
83
Incorrect OP Code
84
Error in ESC-OP code
85
Non-interpretable interrupt (NII)
86
Error in the save routine (SAVE-UP)
87
Stack overflow
88
Semaphore buffer overflow
89
Semaphore buffer not reached
8A
Addressing error by access to an input/output not existing in the process image
90
Unassigned
91
Unassigned
92
Timeout with buffered access to link/local bus *)
93
Timeout with system program processing *)
94
Timeout with LIR/TIR commands *)
95
Timeout with TNB/TNW commands *)
96
Timeout with LPB/LPW/TPB/TPW commands *)
97
Timeout with a substitution command *)
*) Additional information is given on this error in additional fields (see Section 2.2)
2–4

Dynamic system monitoring

Cyclic system monitoring

System errors
Timeouts
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)