04/96
161005
Function abort by NC error ...
Scan
Startup application traversing function
Effect
The traversing function in question aborted
Explanation
Traversing function aborted because of system error or operator action.
General error
1
"Emergency stop"
2
"Warm restart"
Mode Group error
17
"Mode change"
Channel error
33
"Not all channels in reset state"
34
"Reset"
35
"Feed hold" or "feed override = 0"
36
"NC–STOP"
37
"No channel defined"
Axis error
49
"Servo enable"
50
"Parking axis"
51
"Feed hold"
52
"Follow-up"
53
"Axis disable"
54
"Hardware limit switch"
55
"Working area limitation +"
56
"Working area limitation –"
57
"Traversing range +"
58
"Traversing range –"
59
"Error conversion actual value system"
Spindle error
65
"PLC control for spindle"
66
"Spindle reset"
67
"Spindle servo enable"
68
"Setpoint = 0"
69
"Park"
70
"Spindle stop"
Remedy
If system error occurs, start up control again and repeat procedure
161006
Function generator is running
Scan
Startup application function generator
Effect
–
Explanation
Function generator operational message
Remedy
–
161007
Measurement current control loop in progress
Scan
Startup application measuring function current
Effect
–
Explanation
Current controller measuring function operational message
Remedy
–
161008
Measurement position control loop in progress
Scan
Startup application position controller measuring function
Effect
–
Explanation
Position controller measuring function operational message
Remedy
–
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
1–165