Profinet; Profinet Slave Board Installation - Epson RC620 Manual

Robot controller option, fieldbus i/o
Hide thumbs Also See for RC620:
Table of Contents

Advertisement

2. Installation

2.5 PROFINET

2.5.1 PROFINET Slave Board Installation

Appearance
The LED shows the board status.
For details, refer to the section LED Description.
The Fieldbus slave board is configured as follows at shipment.
Board Appearance
CN3
DSW2
DSW1
JMP1
Specifications
Name
Code
Connection Method
Protocol
Device type
Baud Rates (bps)
Maximum segment length 100 m
Cable
Cycle time
Interface
Input Data Size
Output Data Size
124
Status Display LED
RJ45 Connector
Configuration
CN3
All Open
Item
PROFINET board
R12B040707
RT (Real-Time)
PROFINET IO
IO device
100 M bps, full duplex
RJ45 with connector 100BASE-TX (Cat5)
2 msec
RJ45 port × 1
256 bits (32 bytes)
256 bits (32 bytes)
MS LED
CS LED
LNK/ACT LED : Link status /
DSW2
DSW1
SW8
SW7
SW4
SW6
SW3
SW5
SW2
SW4
SW1
SW3
SW2
SW1
All ON
Fixed as above
Specification
RC620 Option Fieldbus I/O Rev.8
: Module status display
: IO Controller
connection status
display
Communication packet
reception or
transmission status
display
JMP1
IRQ15
JP5
IRQ11
JP4
IRQ10
JP3
IRQ7
JP2
IRQ5
JP1
1 2
All Open

Advertisement