71312, DeviceNet I/O device explicit connection
not enabled
Description
DeviceNet I/O device arg does not have the explicit message
connection enabled.
Recommended actions
Change I/O configuration.
71313, Device command order number not unique
Description
The I/O configuration is invalid.
The device command <arg> connected to the I/O device <arg>
has the same order number <arg> as the device command
<arg>.
The order number of device commands connected to the same
I/O device must be unique.
This device command has been rejected.
Recommended actions
Modify the I/O configuration so that device commands on the
same I/O device have unique order numbers.
71315, Max number of device commands
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of device commands in the I/O
system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of device commands) so that the maximum limit is not
exceeded.
71317, I/O device reset
Description
The I/O device arg on the network arg has been reset through
the device command arg, to make sure that the device command
values are activated.
This causes the I/O device to loose contact while it is restarted
but it will regain contact.
Probable causes
A device command for reset has been defined for the I/O device
in the configuration of the I/O system.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
71320, Max number of I/O access levels exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of I/O access levels in the I/O
system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of I/O access levels) so that the maximum limit is not
exceeded.
71321, Invalid I/O access level
Description
The I/O configuration is invalid.
The I/O signal arg has a reference to an invalid/undefined I/O
access level arg.
All I/O signals must either omit the access level or refer to an
existing access level.
This I/O signal has been rejected.
Recommended actions
Change I/O access level to one that exist or define a new I/O
access level.
71323, Invalid bit values
Description
The I/O configuration for I/O signal arg is invalid.
The minimum bit value arg must not be less than arg.
The maximum bit value arg must not exceed arg.
The minimum bit value must be less than the maximum bit
value.
This I/O signal has been rejected.
Recommended actions
Check that the I/O signal is configured with the correct encoding
type. Check that the min and max bit values are correct.
71324, Physical limitation values out of range
Description
The I/O configuration for I/O signal arg is invalid.
The physical limitation minimum value must be less than the
physical limitation maximum value.
This I/O signal has been rejected.
Recommended actions
Correct the physical limitation values for the I/O signal so that
the minimum value becomes less than the maximum value.