The flow arg can not recover from the error situation with
recover action PM_RECOVER_REDO_LAST_PICK.
Program Ref: arg
Consequences
The flow can not be started until a valid recover action has been
set.
Probable causes
The flow can only recover from an error with
PM_RECOVER_REDO_LAST_PICK if the first item is picked
and no items are placed.
Recommended actions
Recover: arg
112382, Project info contains no valid data for
current task
Description
Task: arg
Failed to read project info data.
Program Ref: arg
Consequences
It is not possible to get any information about project settings,
i.e. the names on modules that should be loaded.
Probable causes
The project is already started when a start order from the IO
interface is received.
Recommended actions
Stop project and start it again via the IO interface.
112383, No Running Project
Description
Task: arg
There is no running project and the work area with selection
number or variable name arg can for that reason not be
accessed.
Program Ref: arg
Probable causes
The project has been stopped or is not yet started.
Recommended actions
Recovery: arg
112384, Invalid default height
Description
Task: arg
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
The I/O value of signal arg does not correspond to a valid
default height.
Program Ref: arg
Consequences
It was not possible to set the default height.
Probable causes
The I/O value of arg does not correspond to a valid default
height selection.
Recommended actions
Make sure that arg is set to a proper value before arg is pulsed.
112385, Too many events defined for target
action
Description
Task: arg
Unexpected failure.
More than arg events are configured for a single target action
of type arg
at work area arg.
Program Ref: arg
Consequences
Execution is stopped.
Probable causes
Too many events has been attached to the same target action.
Recommended actions
Modify the project configuration, download and restart the
project.
Contact ABB.
112386, Unknown I/O Trigg type
Description
Task: arg
I/O Trigg type arg is unknown.
Program Ref: arg
Consequences
Stack search can not be completed.
Probable causes
Errors in rapid code.
112393, Flow recover with redo last pick
Description
The Flow arg will redo last unfinished operation at next flow
start.