Document Conventions; Iec 61850 Edition 1 / Edition 2 Mapping - ABB Relion 670 Series Commissioning Manual

Bay control version 2.2 iec
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

1MRK 511 403-UEN E
Although warning hazards are related to personal injury, it is necessary to understand that
under certain operational conditions, operation of damaged equipment may result in
degraded process performance leading to personal injury or death. It is important that the
user fully complies with all warning and cautionary notices.
1.4.2

Document conventions

Abbreviations and acronyms in this manual are spelled out in the glossary. The glossary
also contains definitions of important terms.
Push button navigation in the LHMI menu structure is presented by using the push button
icons.
For example, to navigate between the options, use
HMI menu paths are presented in bold.
For example, select Main menu/Settings.
LHMI messages are shown in Courier font.
For example, to save the changes in non-volatile memory, select Yes and press
Parameter names are shown in italics.
For example, the function can be enabled and disabled with the
Each function block symbol shows the available input/output signal.
Dimensions are provided both in inches and millimeters. If it is not specifically mentioned
then the dimension is in millimeters.
1.5

IEC 61850 edition 1 / edition 2 mapping

Function block names are used in ACT and PST to identify functions. Respective function block
names of Edition 1 logical nodes and Edition 2 logical nodes are shown in the table below.
Table 1:
Function block name
AEGPVOC
AGSAL
ALMCALH
ALTIM
ALTMS
ALTRK
BCZPDIF
Table continues on next page
Bay control REC670
Commissioning manual
The information icon alerts the reader of important facts and conditions.
The tip icon indicates advice on, for example, how to design your project or
how to use a certain function.
the character ^ in front of an input/output signal name indicates that the signal
name may be customized using the PCM600 software.
the character * after an input signal name indicates that the signal must be
connected to another function block in the application configuration to achieve a
valid application configuration.
IEC 61850 edition 1 / edition 2 mapping
Edition 1 logical nodes
© Copyright 2017 ABB. All rights reserved
AEGGAPC
AGSAL
SECLLN0
ALMCALH
-
-
-
BCZPDIF
GUID-96DFAB1A-98FE-4B26-8E90-F7CEB14B1AB6 v8
and
.
Operation setting.
GUID-C5133366-7260-4C47-A975-7DBAB3A33A96 v7
Edition 2 logical nodes
AEGPVOC
AGSAL
ALMCALH
ALTIM
ALTMS
ALTRK
BCZPDIF
Section 1
Introduction
.
15