Download Print this page

Mitsubishi Electric MELFA CR800 Series Special Specifications Manual page 114

For mitsubishi electric rh-1frhr series industrial robot
Hide thumbs Also See for MELFA CR800 Series:

Advertisement

3 Controller
■ Pin layout of connector
1B
1A
1D
1C
Fig.3-23 : Pin layout of connector
■ Connector pin No. and signal assignment
The station number is fixed by the slot to install and the allocation range of the general-purpose input-and-
output signal is fixed.
Table 3-23 : The slot number and the station number
Slot number
SLOT1
SLOT2
The connector pin number of the parallel input-and-output interface installed in SLOT1 and signal number
allocation are shown in
Parallel I/O interface
3-101
Range of the general-purpose input-and-output signal
Station
number
Connector <1>
0
Input : 0 to 15
Output : 0 to 15
1
Input : 32 to 47
Output : 32 to 47
Table 3-24
and
Table
3-25. If it installs in other slots, please interpret and utilize.
20B
Connector<2>
Output 16 to 31
20A
Input
(when station number 0)
20D
Connector<1>
Output 0 to 15
20C
Input
(when station number 0)
16 to 31
0 to 15
Connector <2>
Input : 16 to 31
Output : 16 to 31
Input : 48 to 63
Output : 48 to 63