Download Print this page

Examples Of Safety Measures - Mitsubishi Electric MELFA CR800 Series Special Specifications Manual

For mitsubishi electric rh-1frhr series industrial robot
Hide thumbs Also See for MELFA CR800 Series:

Advertisement

6Safety

6.1.7 Examples of safety measures

Two emergency-stop input circuits are prepared on the user wiring terminal block of the controller.
The safety measure examples are shown in
sures. In addition, the figure shows the normal state which is not in the emergency stop state.
[Note] ・ In the emergency-stop related wiring by the customer, if the coil (is not the contact points) of the relay
prepared by the customer is connected to the controller, please be sure to implement the measure
against the noise by the customer in the coil section. And, please also take the lifetime of noise suppres -
sion parts into consideration.
・ Electric specification of the emergency-stop-related output terminal: 24V DC or less, related current
100mA or less.
・ In the customer's system, do not ground the + side of 24V power supply prepared by customer for con -
nect to the controller. (related with emergency stop and parallel input/output) If it connects with the
controller under the condition that the + side is grounded, it will lead to failure of controller.
<Wiring example 1>: Connect the emergency stop switch of peripheral equipment to the controller.
The power supply for emergency stop input uses the power supply in the controller.
<Operation of the emergency stop>
If the emergency stop switch of peripheral equipment is pushed, the robot will also be in the emergency
stop state.
Fig.6-1 : Example of safety measures (wiring example 1)
Safety
6-131
6-4. Create a circuit as shown below for safety mea -
Fig. 6-1
to
Fig.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Melfa cr800-dMelfa cr800-r