3.6.2 Special stop input (SKIP)

The SKIP is the input signal to stop the robot. Please connect the pin 4, 13 of the CNUSR12 connector shown
in
Fig.
3-11.
Table 3-6 : Special stop input electric specification
Item
Type
No. of input point
Insulation method
Rated input voltage
Rated input current
Working voltage range
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
OFF → ON
time
ON → OFF
Common method
External wire connection method Connector
Page 79 "Fig. 3-10: Wiring method to the user wir -
* Refer to
for more details about how to wire a con -
ing connector"
nector.
Note) In the customer's system, do not ground the + side of 24V power supply prepared by customer for con -
nect to the controller. (related with emergency stop and parallel input/output) If it connects with the con -
troller under the condition that the + side is grounded, it will lead to failure of controller.
Fig.3-11 : Connection of the special-stop-input
Specifications
DC input
1
Photo-coupler insulation
DC24V
Approx. 11mA
DC 21.6 ~ 26.4V (Ripple rate within 5%)
DC 8V or more / 2mA or more
DC 4V or less / 1mA or less
Approx. 2.2 k Ω
1ms or less
1ms or less
1 point per common
Internal circuit
4
1A
330
13
1B
2.2k
Emergency stop input and output etc. 3-80