Point Radiation Commands; Point Radiation Parameters: Prd - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-9 Point Radiation Commands

3-9-1 Point radiation parameters: PRD

Sets the position, time and laser power correction ratio of the point radiation.
Point radiation is a function lasing at a point of the specified coordinate.
Reference
• The data items of PRD command vary depending on the setting details.
• If the object type set in the specified object number is not the point radiation, the laser marker returns the negative
response.
• Use the object creation (CRE) command if you want to create new point radiation objects.
• To adjust the position of the all radiation points set in the object number, use POS command (object coordinates) or POR
command (object movement).
⿎ Setting request data: When setting the radiation points
Start
PRD
code
⿎ Data description
Name
Omit
Object No.
Point No.
(First No. for setting)
Setting/Deleting
Time unit
Radiation time
Laser power
correction
116
[Object No.], [Point No.], [Setting/Deleting],
[Time unit], [Radiation time], [Laser power correction],
S
[X-position], [Y-position] (, [X-position], [Y-position]...)
Max. 23 + 18n-byte
Data
length
[byte]
Max. 4*
"0000"–"1999"
Max. 2*
"00"–"49"
1
"1": Setting
"0": ms
"1": s
1
"2": min
"3": h
With time unit "ms" or "s":
"00000.1"–"99999.9" [ms], [s]
With time unit "min":
Max. 7*
"00000.1"–"02880.0" [min]
With time unit "h":
"00000.1"–"00048.0" [h]
Max. 3*
"000"–"999" [%]
Data content
• Max. 50 points can be set in one object
• Specifies the point no. to be set.
• When setting two or more points, this
To add or edit the radiation point, specify
"1".
• Radiation time and laser power
• The correction ratio of the laser power
• When setting only the radiation time and
ME-LPGS-SR-5
(Check
sum)
Remarks
no.
no. indicates the first no. to be set.
correction settings apply to all points
specified in this command.
is calculated using the value set at the
laser settings as 100%.
laser power correction, end the data
here. No subsequent data including a
separator "," is required.
End code

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents