Panasonic LP-GS Series Serial Communication Command Manual page 148

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

Name
Laser power
correction
Scan speed
correction
Total data length
* Setting request data are variable length.
⿎ Example of command settings
Condition:
Object No. = 0, Laser power correction = 150, Scan speed correction = 80,
Object No. = 1, Laser power correction = 200, Scan speed correction = 100
• Setting
Transmission data
Condition:
Object No. = 0
• Readout
Transmission data
Response data
148
Data
Omit
length
[byte]
Y
Max. 3*
"000"–"999" [%]
Y
Max. 3*
"001"–"999" [%]
It is the length including the separator ",".
Max. 14
The maximum value that can be set to one object number.
Max. 32 objects can be set at once.
[STX]
MOD
[STX]
MOD
[STX]
MOD
Data contents
S
0,150,80,1,200,100
R
0
[CR]
A
0000,150,080
ME-LPGS-SR-5
Remarks
• The correction ratio is calculated
using the value set at the laser
settings as 100%.
• For the point radiation object,
the scan speed correction is not
applied to the marking and its
readout value is always "100" in
the response data for readout
regardless the settings.
[CR]
[CR]