⿎ Timing chart for SIN command transmission
When the file set "Characters specified by SIN command" of string No. 0 and 1 is selected
LASER STANDBY OUT (Y6)
SHUTTER OPEN 1,2 OUT (Y8, Y9) *1
SHUTTER OPEN OUT (No.39) *2
TRIGGER IN (X5)
DATA WAIT OUT (No.38) *2
READY OUT (Y5)
PROCESSING OUT (Y10)
SIN command
Response data
*1 : LP-GS series only
*2 : LP-RF/LP-RC series only
Item
Time
T1
0 ms or more
T2
0 ms or more
Reference
• SIN command can be accepted only when the shutter is open. The shutter status can be confirmed by using SHUTTER
OPEN OUT signal of I/O or STS command.
• When "command reception permission ON" is set by MKM command, SIN command can not be accepted.
• When SIN command will be sent right after file change (FNO/FNN command) or command reception permission OFF
(MKM command) setting, set the wait time of 1 second or more after FNO/FNN/MKM command reception.
• For LP-RC/LP-RF series, you can know the timing of SIN command input by confirming either of the following status.
• DATA WAIT OUT (No.38) signal of I/O connector is ON.
• Data waiting status in the response data of STS command is "1".
• When the file with "Characters specified by SIN command" function is selected, transmit this command by every marking
triggers. Otherwise marking trigger ready does not turn ON, and marking is not available.
• It is not possible to send SIN command twice or more to one string number for one marking trigger.
• To reset the transmitted SIN command data, either close the shutter, or set "command reception permission ON" for
MKM command.
ON
OFF
ON (Open)
OFF (Close)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
SINS0,aaaa,1,bbbb
Remarks
Before sending SIN command, confirm that the shutter is opened.
For LP-RC/LP-RF series, you can use either SHUTTER OPEN OUT signal or DATA
WAIT OUT (No.38) to know the timing of SIN command input.
After confirming PROCESSING OUT (Y10) is turned ON, the next SIN command data
can be sent.
For LP-RC/LP-RF series, you can use either PROCESSING OUT signal or DATA WAIT
OUT (No.38) to know the timing of SIN command input.