Panasonic LP-GS Series Serial Communication Command Manual page 167

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

Troubles
The requested operation can
be controlled only by I/O with
the current system settings.
"Reception mode ON"
is not set for command
reception permission (MKM
command).
The sending
command is not
accepted and
negative response is
returned.
Alarm or Warning occurred.
Two or more command data
are transmitted at the same
time.
Command mode (LP-400/V
compatibility setting) is wrong.
* These commands are applicable with the standard command mode. For the LP-400/V compatible mode, refer to the "Serial
Communication Command Guide: LP-400/V compatible mode".
Causes
To control the following commands with the serial
communication, specify the control method to the
communication command in Laser Marker NAVI smart system
settings and restart the laser marker.
• Laser pumping (LSR)
• Shutter open/close (SHT)
• Guide Laser (GID) (LP-GS051(-L) type, LP-RC350S and LP-
RF series only)
The following commands are available only when the shutter
open/close control method is set to communication command.
• Laser radiation for measurement (SPT)
Except the following commands *, the laser marker cannot
accept the command unless it is in the "reception mode ON"
status. For command transmission, set "reception mode ON" by
MKM command.
• File selection by number (FNO)
• File selection by name (FNN)
• Shutter open/close (SHT)
• Command reception permission (MKM)
• Laser pumping (LSR)
• Counter reset (CTR)
• Status checking (STS)
• Marking trigger (MRK)
• Character entry per trigger (SIN)
• Marking position and laser power adjustment per trigger (SEO)
All commands except the following commands * cannot be
accepted while alarm or error is active.
When alarm occurred:
• Status checking (STS)
• Alarm reset (ARS)
• Error number (ENO)
When warning occurred:
• Status checking (STS)
• Alarm reset (ARS)
• Error number (ENO)
• Shutter open/close (SHT) (Only for closing request, and
readout)
• Command reception permission (MKM) (readout only)
After sending the command, confirm the response data from the
laser marker. Do not send the next command before receiving
the response.
• If you want to use the same command format with the
previous models of LP-400/LP-V series, enable "LP-400/V
compatibility" in system settings of Laser Marker NAVI smart.
• If you want to use the standard command format, switch the
mode by RSM command or disable "LP-400/V compatibility"
in system settings of Laser Marker NAVI smart.
ME-LPGS-SR-5
Measures
167

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents