3-3-6 Trigger mode: TMS

Specifies how you will input TRIGGER IN (marking start signal) to a static object by selecting "single trigger" or "continuous
trigger". According to this setting, the behavior of TRIGGER IN signal in I/O terminal is defined. Trigger mode setting is
applied to only the selected file.
⿎ Setting request data / response data for readout
Start
TMS
code
command
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
TMS
code
⿎ Data description
Name
Omit
Trigger mode
Allow to stop
Y
halfway
Minimum number
Y
of scans
Maximum number
Y
of scans
Scan interval
Y
Total data length
* Setting request data are variable length.
[Trigger mode], [Allow to stop halfway],
[Minimum number of scans], [Maximum number of scans],
Sub
With single trigger: 1-byte
With continuous trigger: Max. 18-byte
R
(Check sum)
Data length
Data content
[byte]
"0": Single trigger
1
"1": Continuous trigger
"0": Do not allow
1
"1": Allow to stop
Max. 4*
"0001"–"9999" [times]
"0001"–"9999" [times]
Max. 4*
"0000": No upper limit
Max. 4*
"00.0"–"60.0" [sec.]
1
• When the trigger mode is single trigger: 1-byte (Fixed-length)
or
• When the trigger mode is continuous trigger: Max. 18-byte (Length
Max. 18
including separator ",")
[Scan interval]
End code
• With "single trigger", one lasing operation
is executed by each input of TRIGGER
IN.
• With "continuous trigger", lasing operation
is repeated while TRIGGER IN is on.
• With setting "0": Single trigger, end the
data here. Do not send any subsequent
data including a separator ",".
• Specify these values only when the
trigger mode is continuous trigger. When
the trigger mode is single trigger, do not
input anything.
• Without "allow to stop halfway" setting if
TRIGGER IN turns OFF when the lasing
operation is running, the lasing operation
is terminated after finishing the running
operation.
• With "allow to stop halfway" setting when
the marking operation stops halfway
because TRIGGER IN turns OFF, it is
counted as one normal scanning.
• Minimum number of scans should be
less than or equal to maximum number of
scans.
ME-LPGS-SR-5
(Check
End code
sum)
Remarks
63