2-3-4 Omitting request data

Some of the data items can be omitted depending on the command if you specify more than one data item to the variable-
length data part of the request data.
The data set last (the initial value if it was not set) will be maintained for the data item omitted. Any other operations are
explained at each command description.
⿎ How to omit data item
• Enter a separator "," only for the data item you want to omit.
• Do not specify any data including the separator "," if you want to omit all the subsequent items. (Set 0 byte)
Example of data omission
• When you specify certain items of the following format data items and omit the rest
Start code
ALC
When you specify X-movement = 10 mm only and maintain the last specified value (or the initial value) for the rest
[STX]
ALC
S
10
When you specify Rotation movement = 180° only and maintain the last set value (or the initial value) for the rest
[STX]
ALC
S
,,,180
36
[X-movement], [Y-movement], [Z-movement],
S
[Rotation movement],
[Y-axis mirroring], [X-axis mirroring]
[CR]
[CR]
ME-LPGS-SR-5
End code