Panasonic LP-GS Series Serial Communication Command Manual page 35

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

Sub
Response
response
code
code
"11"
"00"
"12"
"00"
"13"
"00"
"14"
"00"
"16"
"00"
"17"
"00"
"18"
"00"
"19"
"00"
"96" *1
"01"–"99"
"97" *1
"01"–"99"
"98" *1
"01"–"99"
"99"
"00"
*1 : For this response code, the data number with an error will be displayed at the sub response code.
Example of negative response
• Negative response to the file number change request (FNO command)
Start code
Command
STX
"FNO"
02
46 4E 4F
Error cause
SIN or SEO command is not acceptable.
• The internal shutter status is closed.
• The MKM command is set to "command reception permission ON".
• The character data has been already transmitted to the specified string No. in SIN
command.
• SEO command was sent without enabling "Using SEO command" setting in external
offset function.
• SEO commands were sent more than twice for one marking.
Unable to register data due to a lack of memory capacity.
Nothing is set to the object number/object group number specified. (Data have not been
created)
Not available command with this laser marker model.
The command not allowed for the marking data of the object number specified.
• Object type is unfit for the command.
• The graphic object other than VEC format is set in the object No. specified with CDF
command or CDC command.
• The selected object number is available only to the specific type of barcode or 2D code.
Not available command with this laser marker version.
Unacceptable command because laser pumping is off or not completed.
• SPT command for starting radiation request is sent when laser pumping is not ready.
• LP-RC series only: SHT command for opening shutter request is sent when laser
pumping is off.
Unacceptable command with current settings of trigger mode.
Necessary data item is omitted.
Incorrect value (out of setting range) is included in the variable-length or fixed-length data
part.
Invalid value was specified in the variable-length or fixed-length data part.
• It has exceeded the maximum data length.
• It includes a character that is not allowed.
• The data item value including the decimal point is invalid.
• The data item value including the plus (+)/minus (-) sign is invalid.
Others
Sub command
"E"
45
ME-LPGS-SR-5
Data example:
Check sum
"9801"
39 38 30 31
46 43
It indicates that the first line (01) of the data part
is invalid.
End code
CR
0D (HEX)
35