3-5 Character Setting Commands

3-5-1 Character entry: STR

Sets the characters of the character objects (except reference list type), bar code/2D code objects.
⿎ Setting request data
Start
STR
code
⿎ Readout request data
Start
STR
code
⿎ Response data for readout
Start
STR
code
⿎ Data description
Data length
Name
Object No.
Max. 6*
Marking character
Max. 598
Total data length
Max. 605
* Setting request data are variable length.
[Object No.], [Marking character]
S
(,[Object No.], [Marking character]...)
[Object No.]
R
Max. 6-byte
[Object No.], [Marking character]
A
Max. 605-byte
Data contents
[byte]
For character objects, bar code/2D
code objects excepting 2D side of
composite code:
"0000"–"1999" or "0000.0"–"1999.0"
For 2D side of composite codes:
"0000.1"–"1999.1"
The number of input characters
allowed is max. 299 characters.
It is the length including the separator ",".
The maximum value that can be set to one object number.
Max. 32 objects can be set at once. Note that the total data length of one request
data should be less than 4096-byte.
(Check
End code
sum)
(Check
sum)
• Excepting 2D side of the composite
• To set the character to 2D side of the
• Only "0" or "1" can be specified after
Specify 0-byte for data length to delete
characters.
ME-LPGS-SR-5
(Check
End code
sum)
End code
Remarks
codes, you do not need to specify the
number after the decimal point.
composite codes, add ".1" after the
object number.
the decimal point.
75