NEC Aspila Topaz Programming Manual page 143

Intelligent hybrid system
Hide thumbs Also See for Aspila Topaz:
Table of Contents

Advertisement

IN
SA
20-07: Class of Service Options (Administrator Level)
SB
Input Data(Cont'd)
Prog. No.
20-07-14
VRS General Message Listen
Enables/disables extension's ability to dial 4 or Service
Code 711 and listen to the General Message
20-07-15
VRS General Message Record
Enables/disables extension's ability to dial Service Code
712 and record, listen to or erase the General Message
20-07-16
-Not Used-
20-07-17
-Not Used-
20-07-18
SMDR printout accumulated extension data
20-07-19
SMDR printout accumulated STG data
20-07-20
SMDR printout accumulated account code data
*All Classes are above mentioned default value.
Conditions
None
Feature Cross Reference
Class of Service
Telephone Programming Instructions
To enter data for Program 20-07(Class of Service Options(Administrator Level)):
1. Enter the programming mode.
2. Enter 20 07
20-07-01 F-Cls1  
SW Man NT serv 0
3. Enter the number of the item you want to program.
20-07-xx F-Clsxx
xxxxx
4. Select the Class of Service number to be programmed by pressing the FLASH or the VOLUME
VOLUME
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Program 20: System Option Setup
Item
135
Input Data
Default*
1
1
0 : Off
1 : On
-
-
0
0
0
or
Programming Manual
Related
Program
11-10-21
11-10-22
11-10-23
11-10-24
11-10-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents