NEC Aspila Topaz Programming Manual page 340

Intelligent hybrid system
Hide thumbs Also See for Aspila Topaz:
Table of Contents

Advertisement

Program 81:
81-01: Analogue Trunk Initial Data Setup
Input Data(Cont'd)
Prog. No.
Pulse Dial Break Time (10pps)
81-01-27
Pulse Dial Make Time (10pps)
81-01-28
Inter-digit Time (10pps)
81-01-29
81-01-30
Pulse Dial Break Time (20pps)
81-01-31
Pulse Dial Make Time (20pps)
81-01-32
Inter-digit Time (20pps)
81-01-33
Charging Pulse Minimum Duration Time
81-01-34
Charging Pulse Minimum Period Time
81-01-35
Charging Pulse Minimum Interval Time
Conditions
None
Feature Cross Reference
Central Office Calls, Placing
Telephone Programming Instructions
To enter data for Program 81-01 (Analogue Trunk Initial Data Setup):
1. Enter the programming mode.
2. Enter 81 01
81-01-01
Compand'n Type0
3. Enter the number of the item you want to program.
81-01-xx
xxxxx
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Programming Manual
Basic Hardware Setup for Trunk
Item
332
Input Data
1-255 (8-2040mS)
1-255 (8-2040mS)
1-255 (32-8160mS)
1-255 (8-2040mS)
1-255 (8-2040mS)
1-255 (32-8160mS)
1-255 (8-2040mS)
1-255 (8-2040mS)
1-255 (8-2040mS)
IN
SA
SB
Default
13(104ms)
7(56ms)
19(608ms)
6(48ms)
4 (32ms)
16 (512ms)
9 (72ms)
29 (232ms)
6 (48ms)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents