Program 90: Maintenance Program
90-13: System Information Output
Description
Use Program 90-13 : System Information Output to define the output port to be used as the system information
output. The baud rate for the COM port should be set in Program 10-21-02.
Input Data
Prog.No.
Output Port Type
90-13-01
Indicate the type of connection used for the
SMDR.
90-13-02
-Not Used-
Dialing 1 from this program sends the system
90-13-03
report to the connected device.
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 90-13 (System Information Output):
1. Enter the programming mode.
2. Enter 90 13
90-13-01
 
Output Type
0
3. Enter the number of the item you want to program.
90-13-xx
xxxxx
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Programming Manual
Item
366
Input Data
0...No setting
1...COM Port (EXIFU)
-
Dial 1 and press HOLD
(Press only HOLD key for
cancel)
IN
SA
SB
Default