NEC Aspila Topaz Programming Manual page 28

Intelligent hybrid system
Hide thumbs Also See for Aspila Topaz:
Table of Contents

Advertisement

Program 10: System Configuration Setup
10-06: ISDN BRI Setup
Description
Use Program 10-06 : ISDN BRI Setup defines the TEI selection and DID mode for DID callers when the BRI
feature is used. Previously, if the called party number did not match the SPID number, the system would not allow
the call to go through. And to enter the SPID (Service Profile ID) assigned to each of the system's BRI ISDN
lines. Each BRI PCB has a maximum of two lines and each line can have a maximum of two SPIDs.
To use both channels of a BRI ISDN line, two directory numbers must be ordered from telco. A SPID will be
assigned for each directory number.
Input Data
SLOT No.
ISDN Line No.
Prog. No.
Item
10-06-01
TEI selection
DID mode
10-06-02
10-06-03
SPID1
SPID2
10-06-04
Conditions
None
Feature Cross Reference
ISDN Compatibility
Telephone Programming Instructions
To enter data for Program 10-06 (ISDN BRI Setup):
1. Enter the programming mode.
2. Enter 10 06
10-06-01SlotNo1
BRI TEI
0
3. Enter the number of the item you want to program.
10-06-xxSlotNox
xxxxx
4. Select the Slot Number to be programmed by pressing the FLASH or the VOLUME▲ or VOLUME▼ keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Programming Manual
Input Data
0 : Select by SPID number
1 : Select by Channel ID Number
0 : Route by Called Party Number
1 : Route by Redirecting Number
Dial (Up to 20 digits)
20
5,6,11,12,17,18
1-4
Default
Description
0
0
No setting
IN
SA
SB