IN
SA
SB
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate an alarm as
Major or Minor. This program also assigns whether or not the alarm is displayed to a key telephone and whether or
not the alarm information is reported to the pre-defined destination.
Input Data
Alarm Number
Prog.No.
Item
90-10-01
Alarm Type
90-10-02
Report
Default
Alarm
Type
Report
1
2(MIN)
0
2
2(MIN)
0
3
2(MIN)
0
4
2(MIN)
0
5
0
0
6
0
0
7
1(MAJ)
0
8
1(MAJ)
0
9
0
0
Program 90: Maintenance Program
0 : Not set
1 : Major Alarm
2 : Minor Alarm
0 : Not report (No Auto-Dial)
1 : Report (Auto-Dial)
Note
Is Used To Advise of........
Board Initialization
Initialization Failure or the
Error
PCB is defective
Board
Installation
PCB was unplugged without
Error
using the proper procedure.
Communication
PCB communication failure
Error between
has occurred.
Board and EXIFU
PCB Program
Download may have failed
Download Error
because
blocked(disabled) or the sub
-program does not exist on
the system flash card.
-Not Used-
-
Blocking (No
Failure may have occurred
default setting)
because:
• Terminal blocking
detected.
• Terminal is unplugged.
• Wire is disconnected.
• 308 card is defective.
-Not Used-
-
RAM
Backup
RAM backup battery on the
Battery Error
308M PCB is unplugged or
defective.
-Not Used-
-
361
90-10: System Alarm Setup
001-100
Input Data
Remove and reinstall the
PCB.
Check the PCB installation.
Remove and reinstall the
PCB. If RECover message is
received in the alarm report,
the PCB is good. If not,
replace with a new PCB.
After unblocking the PCB, if
the
PCB
is
RECover
received in the alarm report,
it is corrected. If not, then
replace the system flash
card.
-
Check the terminal wiring
and reconnect properly.
Then unplug and plug in the
PCB. If RECover message is
received in the alarm report,
it is correct. If not, replace
the PCB and/or
terminal.
-
Check the battery connector.
If it is connected correctly,
then replace the battery.
-
Programming Manual