IN
SA
SB
Description
Use Program 90-12 : System Alarm Output to set the options for the alarm report. This program has
menu options. Define the output port to be used as the output for system alarm report and set the system alarm
options. The system can have up to 50 reports.
Input Data
Prog.No.
Output Port Type
Indicate the type of connection used for the System
90-12-01
Alarms. The baud rate for the COM port should be
set in Program 10-21-02.
90-12-02
-Not Used-
90-12-03
Output All Alarm Reports
90-12-04
Printout New Alarm Reports
90-12-05
Clear All Alarm Reports
90-12-06
Output Mode
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 90-12 (System Alarm Output):
1. Enter the programming mode.
2. Enter 90 12
90-12-01
 
Output Type 0
3. Enter the number of the item you want to program.
90-12-xx
xxxxx
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section
Program 90: Maintenance Program
90-12: System Alarm Output
Item
365
Input Data
0 : No setting
1 : COM Port (EXIFU)
-
Print All? (Yes : 1)
Print New? (Yes: 1)
All Clear? (Yes : 1)
0 : Manual
1 : Auto
Programming Manual
6
separate
Default
0
-
-
-
-