NEC Express5800 Series Maintenance Manual page 128

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 2 Convenient Features
13. On the configuration menu of each logical port, put a cursor onto [iSCSI Offload Protocol] and select
[Enabled].
Press the <ESC> key to return to NIC Partition Configuration menu.
Make sure that the port you have configured is changed to "Eth : iSCSI".
If you want to configure any other logical port, repeat Steps 12 through 14.
14. Press the <ESC> key to return to Device List menu.
If you configure any other device, repeat Steps 8 through 14.
15. Press the <ESC> key to return to Exit Configuration menu, and select [Exit and Save Configurations].
16. Press any key to exit Configuration Menu.
128
Tips
In NPAR mode, up to two protocols can be set to [Enabled] per a port.
Express5800/B120e-h Maintenance Guide
12. Advanced LAN Configuration