4-76 Configuring Your Server
Described below are procedures based on assumption:
One of the hard disk drives failed in a RAID1 VD configured with two hard disk drives.
Replace the failed hard disk drive with new one after turning off the power of the server. Auto
Rebuild feature is disabled for non-hot-swap replacement. Use Manual Rebuild feature to recover
the virtual drives as described below.
1.
Start WebBIOS.
Make sure that the status for the replaced hard disk drive is indicated as "Unconfigured
Good" in the right frame of the Top Menu.
In the example below, the hard disk drive in slot number 1 has been replaced.
The indication "PD Missing: BackPlane 252: Slot 1" represents that the hard disk drive in
VD having been installed in slot number 1 was removed.
2.
Select the newly connected hard disk drive (the hard disk drive in slot number 1 in the
example) from the right frame of Top Menu.
3.
The properties for Physical Drive is displayed.