8-8 Troubleshooting
On-screen error message
Some configured disks have been removed from your system,
or are no longer accessible. Please check your cables and also
ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
The battery hardware is missing or malfunctioning, or the
battery is unplugged.
If you continue to boot the system, the battery-backed cache
will not function. Please contact technical support for
assistance. Press 'D' to disable this warning (if your controller
does not have a battery).
The cache contains dirty data, but some VDs are missing or will
go offline, so the cached data can not be written to disk. If this is
an unexpected error, then please power off your system and
check your cables to ensure all disks are present. If you
continue, the data in cache will be permanently discarded.
Press 'X' to acknowledge and permanently destroy the cached
data.
The following VDs are missing: xx
If you proceed (or load the configuration utility), these VDs will
be removed from your configuration. If you wish to use them at
a later time, they will have to be imported. If you believe these
VDs should be present, please power off your system and
check your cables to ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
The following VDs have missing disks: xx
If you proceed (or load the configuration utility), these VDs will
be marked OFFLINE and will be inaccessible.
Please check your cables and ensure all disks are present.
Press any key to continue, or 'C' to load the configuration utility.
Your VDs that are configured for write-back are temporarily
running in write-through mode. This is caused by the battery
being charged, missing, or bad.
Please allow battery to charge for 24 hours before evaluating
battery for replacement.
The following VDs are affected: XX
Press any key to continue.
IMPORTANT:
displayed due to insufficient expansion ROM area. Select one of the
features of the lowest frequency and set it to "Disabled".
– On board LAN 1/On board LAN 2
– PCI slot 1
The message "Expansion Rom not initialized" may be
Action
Check if hard disk drives are
connected properly. If the same
error persists, contact your
service representative.
Press D to hide this message.
Check if hard disk drives are
connected properly. If the same
error persists, contact your
service representative.NOTE: If
you press X, the data in cache
memory will be lost.
Check if hard disk drives are
connected properly.
If the same error persists,
contact your service
representative.
Check if hard disk drives are
connected properly.
If the same error persists,
contact your service
representative.
It is no problem if the message is
logged without battery.
There is no additional battery for
the controller, so ignore this
message.