NEC Express5800/B120b User Manual page 96

Express5800/bladeserver series;
Table of Contents

Advertisement

4-46 Configuring Your Server
Notes on Creating Virtual Drive
1.
The hard disk drives configuring the drive group should have the same capacity and
rotation speed.
2.
Be sure to execute Consistency Check after creating VD.
3.
When installing an OS in VD under N8403-026 RAID controller, create a VD dedicated to
OS installation.
4.
WebBIOS cannot be handled via remote console functions of NEC ESMPRO Manager.
5.
The physical drive numbers shown in WebBIOS and those shown in Universal RAID
Utility are identified as follows.
– WebBIOS
Slot number shown in Physical View *
*1: The slot number, type of hard disk drive, its capacity, and its current status are
shown in Physical View.
The slot number is indicated by the number 0 or 1. It represents the slot number in
the hard disk drive.
– Universal RAID Utility
ID shown in Hard disk drive Properties
The slot number shown on WebBIOS corresponds to the hard disk drive ID shown
on Universal RAID Utility. For more information, refer to the Universal RAID
Utility Ver2.0 User's Guide.
Physical View of WebBIOS

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8400-110fN8400-114f

Table of Contents