NEC Express5800/B120b User Manual page 231

Express5800/bladeserver series;
Table of Contents

Advertisement

On-screen error message
Foreign configuration(s) found on adapter
Press any key to continue, or 'C' to load the configuration utility.
Invalid SAS Address present in MFC data. Please program
valid SAS Address, and restart your system.
Invalid SAS topology detected. Please check your cable
configurations, repair the problem, and restart your system.
Invalid memory configuration detected.
Please contact your system support.
System has halted.
Memory/battery problems were detected.
The adapter has recovered, but cached data was lost.
Press any key to continue, or 'C' to load the configuration utility.
Multibit ECC errors were detected on the controller.
DIMM on the controller needs replacement. If you continue,
data corruption can occur. Press 'X' to continue or else power
off the system and replace the DIMM module and reboot. If you
have replaced the DIMM please press 'X' to continue.
Multiple Single-bit ECC errors were detected during the
previous boot of the controller. DIMM on the controller needs
replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the system and replace
the DIMM module and reboot. If you have replaced the DIMM
please press 'X' to continue.
Previous configuration cleared or missing
Importing configuration created on MM/DD hh:mm
Press any key to continue, or 'C' to load the configuration utility.
RAID Adapter
FW Failed Validation!!!
Adapter needs to be reflashed.
Press any key to continue.
SAS drives were detected, but this controller does not support
SAS drives.
Please remove the SAS drives then restart your system.
Press any key to continue, or 'C' to load the configuration utility.
SATA drives were detected, but this controller does not support
SATA drives.
Please remove the SATA drives then restart your system. Press
any key to continue, or 'C' to load the configuration utility.
Single-bit overflow ECC errors were detected during the
previous boot of the controller. DIMM on the controller needs
replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the system and replace
the DIMM module and reboot. If you have replaced the DIMM
please press 'X' to continue.
Troubleshooting 8-7
Action
Press C to run the utility to import
or clear configuration.
Please contact your service
representative.
Check if RAID Controller is
connected properly. If the same
error persists, contact your
service representative.
Contact your service
representative to replace the
RAID Controller.
Please contact your service
representative.
Contact your service
representative to replace the
RAID Controller
Contact your service
representative to replace the
RAID Controller
Please contact your service
representative.
Contact your service
representative to replace the
RAID Controller.
RAID Controller may be faulty.
Contact your service
representative to replace the
RAID Controller.
RAID Controller may be faulty.
Contact your service
representative to replace the
RAID Controller.
Contact your service
representative to replace the
RAID Controller

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8400-110fN8400-114f

Table of Contents