8-4 Troubleshooting
On-screen error message
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
0B66
DIMM group #7 has been disabled
0B67
DIMM group #8 has been disabled
0B70
The error occurred during temperature sensor
reading
0B71
System Temperature out of the range
0B74
The error occurred during voltage sensor reading Contact your service representative.
0B75
System Voltage out of the range
0B78
The error occurred during fan sensor reading
0B7C The error occurred during redundant power
module confirmation
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A BMC SEL area full.
0B8B BMC progress check timeout
0B8C BMC command access failed.
0B8D Could not redirect the console
- BMC Busy -
0B8E Could not redirect the console
- BMC Error -
0B8F Could not redirect the console
- BMC Parameter Error -
0B90
BMC Platform information Area Corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
Action
Contact your service representative.
Contact your service representative.
The fan may be faulty, or dusts are
clogged in fan.
Contact your service representative for
maintenance.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
Run SETUP and select [Server] - [Event
Log Configuration] - [Clear All Error Logs]
to clear error logs.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
FRU command and EMP feature are
unavailable. This is not a fatal error,
however, power-off and reboot the CPU
blade. If the error persists, contact your
service representative.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
Access to SMC via IPMB is unavailable.
This is not a fatal error, however, power-
off and reboot the CPU blade. If the error
persists, contact your service
representative.

Advertisement