Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 113

Table of Contents

Advertisement

 Point table (FR-A800)
Set parameters related to point tables.
Setting range
Minimum
increments
Symbol
A
No.
B
Target position
C
Maximum speed
D
Acceleration time
E
Deceleration time
F
Dwell time
G
Sign
H
Command method
I
Operation method
 Point table (FR-E800)
Set parameters related to point tables.
Setting range
112
3. FUNCTION
3.1 Parameter list
A
B
Name
Function/description
Point table number
Set the position feed length. (Refer to Pr.465 to Pr.494.)
Set the maximum speed for the target parameter of each point table. If a checkbox is selected, the
maximum speed of the point table 1, 2, or 3 is applied ("9999" is set in the corresponding
parameter (Pr.24 to Pr.27, and Pr.232 to Pr.239)).
Set the acceleration time for the target parameter of each point table.
Set the deceleration time for the target parameter of each point table.
Set the waiting time before starting the position command of the next point table.
Select the polarity of position data.
Select the absolute or incremental position command.
Select the individual, continuous, or repeat operation.
When continuous operation is selected, next point table is executed after a command has been
executed. For continuous operation, select "individual" in [Operation method] of the last point
table.
Individual operation executes the selected point table only.
When repeat operation is selected, the selected positioning operation is repeated.
Minimum
increments
A
B
C
D
E
F
C
D
E
G
H
I
F
G
H