Pr.
Name
1442
IP filter address 1 (Ethernet)
N660
1443
IP filter address 2 (Ethernet)
N661
1444
IP filter address 3 (Ethernet)
N662
1445
IP filter address 4 (Ethernet)
N663
1446
IP filter address 2 range specification
N664
(Ethernet)
1447
IP filter address 3 range specification
N665
(Ethernet)
1448
IP filter address 4 range specification
N666
(Ethernet)
1449
Ethernet command source selection IP
N670
address 1
1450
Ethernet command source selection IP
N671
address 2
1451
Ethernet command source selection IP
N672
address 3
1452
Ethernet command source selection IP
N673
address 4
1453
Ethernet command source selection IP
N674
address 3 range specification
1454
Ethernet command source selection IP
N675
address 4 range specification
NOTE
• Always reset the inverter after making the setting of the parameters. After you have changed the communication-related
parameters, communication cannot be established until the inverter reset.
• Set "5001" in any parameter from Pr.1076 to Pr.1078 to enable automatic recognition or switching to online connection during
communication through "CPU module" or "Ethernet module". When the initial settings are used, there is no need to change.
(Refer to
page
72.)
• FR-E700-NE
Pr.
Name
442
Default gateway address 1
443
Default gateway address 2
444
Default gateway address 3
445
Default gateway address 4
NET mode operation command
550
source selection
805
Ethernet IP address 1
806
Ethernet IP address 2
807
Ethernet IP address 3
808
Ethernet IP address 4
809
Subnet mask 1
810
Subnet mask 2
811
Subnet mask 3
812
Subnet mask 4
Ethernet communication network
830
number
Ethernet communication station
831
number
Link speed and duplex mode
832
selection
Initial
Setting range
value
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
9999
0 to 255, 9999
9999
0 to 255, 9999
9999
0 to 255, 9999
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
9999
0 to 255, 9999
9999
0 to 255, 9999
Initial
Setting range
value
0
0 to 255
Enter the IP address of the default gateway, which is a
0
0 to 255
device connecting the different networks, to establish a
communication between the inverter and the devices
0
0 to 255
outside the inverter network.
0
0 to 255
The Ethernet connector is the command interface enabled
0
in the NET operation mode.
0
The PU connector is the command interface enabled in the
2
NET operation mode.
192
0 to 255
168
0 to 255
Enter the IP address of the inverter to be connected to
Ethernet.
50
0 to 255
1
0 to 255
255
0 to 255
255
0 to 255
Enter the subnet mask of the network to which the inverter
belongs.
255
0 to 255
0
0 to 255
1
1 to 239
Enter the network number.
1
1 to 120
Enter the station number.
Set the communication speed and the communication
0
0 to 4
mode (full-duplex/half-duplex).
Description
Set the range of connectable IP addresses for the
network devices.
(When Pr.1442 to Pr.1445 = "0 (initial value)", the
function is invalid.)
Set the range of IP addresses to limit the network
devices that can be used as a command source during
Ethernet communication (with MODBUS/TCP
protocol).
When Pr.1449 to Pr.1452 = "0 (initial value)", no IP
address is specified for command source selection via
Ethernet. In this case, operation commands cannot be
sent via Ethernet with MODBUS/TCP protocol.
When four or more clients attempt a connection to the
inverter during MODBUS/TCP protocol
communication, the connection attempted from
outside of the IP address range set for Ethernet
command source selection may be forced to be
closed.
Description
1.4 Connection and parameter setting
1
2
3
4
5
6
7
8
9
10
43
1. OUTLINE