• For using the Ethernet parameter setting, connect the inverter and the personal computer directly via Ethernet or using a hub.
• The inverter and the personal computer must have the same IP address. If they have different IP addresses, the network
number and the station number cannot be set.
• The LED all-OFF setting and the connection check ON/OFF setting are available for FR-E800-E inverters connected directly
by Ethernet.
• Those settings are enabled when online communication is established between the inverter and FR Configurator2.
• LEDs may not blink depending on the Pr.1399 setting even when the connection check is enabled. Refer to the Instruction
Manual of the inverter for the details.
• When FR-E800-E inverters are connected in line topology, writing to two or more inverters at the same time may cause a
communication error.
C
D
E
F
G
M
N
Detects the inverter(s) connected via Ethernet to read and indicate the parameters.
Select the target inverter(s) to perform [Batch assign] or [Write].
Shows the model of the connected inverter.
Shows the capacity of the connected inverter.
Set the inverter network number. (For FR-A800-E, FR-F800-E, and FR-E800-(SC)E, refer to
Pr.1424. For FR-A800-E-R2R, refer to Pr.1073. For FR-E700-NE, refer to Pr.830.)
Set the inverter station number to be written to the inverter. (For FR-A800-E, FR-F800-E, and FR-
E800-(SC)E, refer to Pr.1425. For FR-A800-E-R2R, refer to Pr.1074. For FR-E700-NE, refer to
Pr.831.)
Shows the MAC address of the connected inverter.
Set the host name to be written to the inverter. Up to 16 characters can be entered. Single-byte
letters and numbers, hyphens (-), periods (.), colons (:), and underscores (_) can be entered.
Enter the IP address to be written to the inverter.
Enter the Subnet mask to be written to the inverter.
Used to turn ON the NET LEDs on successfully connected inverters to blink in the communication
ON
check of FR Configurator2. (The blinking of LEDs will automatically stop five minutes after the start
of blinking.)
Used to stop the blinking of the NET LEDs on successfully connected inverters in the
OFF
communication check of FR Configurator2.
Selects all inverters in the list.
Clears selection of all inverters in the list.
Selects inverters for which the series name is indicated in the model field.
Used to stop the blinking of the NET LEDs on all successfully connected inverters.
Shows the batch assignment dialog.
Writes the network number, station number, host name, IP address, and subnet mask to the
inverters with a check in the checkbox.
H
I
J
O
Function/description
3.12 Ethernet parameter setting function
K
Q
P