Communication Error With The Got - Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual

Table of Contents

Advertisement

Error code (HEX)
Communication was not
0x90010101
established with the inverter
within the timeout time.
The communication line cannot
0x90A00101
be opened.
0x90F00001
The communication settings
cannot be written.
0x90F00002
4.1.2

Communication error with the GOT

NOTE
• If a timeout error occurs, set the FR Configurator2 to the offline mode. Check the connection of the communication cable, etc.,
and remove any error causing condition, then set it to online.
• The parameter list of FR Configurator2 shows the parameters of the latest inverter at the time of the FR Configurator2 upgrade.
(For the upgrade timing of FR Configurator2, refer to
be different before and after a version upgrade (with functions added).
• Refer to
page 214
Error code (HEX)
An unexpected error occurred in
0x80110001
S/W.
0x80110002
An unexpected error occurred in
0x80110003
S/W.
Communication was not
0x80110004
established with the inverter
within the timeout time.
Communication was not
0x80110005
established with the inverter
within the timeout time.
Communication was not
0x80110006
established with the inverter
within the timeout time.
An unexpected error occurred in
0x80110007
S/W.
An unexpected error occurred in
0x80110008
S/W.
Communication was not
0x80110009
established with the inverter
within the timeout time.
Communication was not
0x8011000A
established with the inverter
within the timeout time.
Error message
PROFINET is selected in any of
Pr.1427 to Pr.1430 Ethernet
function selection.
The IP address is used by another
inverter.
The inverter series name is
unknown.
The inverter model is unknown.
for information on communication errors with the GOT (error codes: 0x01808301 and 0x0180840B).
Error message
GOT type error.
Please contact your sales representative.
• Communication protocol of the
inverter and the GOT are not the
same.
• Setting of Pr.122 PU
communication check time
interval, Pr.336 RS-485
communication check time
interval, Pr.548 USB
communication check time
interval is other than "0".
• Electromagnetic interference
• Cable breakage/damage
GX drawing software was started
when FR Configurator2 was
starting.
GX drawing software was started
when FR Configurator2 was
starting.
Communication line quality error
Baud rate not supported by
connected device
• Electromagnetic interference
• Cable breakage/damage
Other process is ongoing in the
GOT and line is BUSY.
(retry is performed in the
EZSocket)
A station not connected is being
monitored.
Possible cause
page
227.) The parameters' setting range, initial value, and numbers may
Possible cause
Countermeasure
Do not set "34962" in any of Pr.1427
to Pr.1430 Ethernet function
selection.
Set a unique IP address.
• Upgrade FR Configurator2 to the
latest version.
• Write the communication settings
from the operation panel. For
information on the communication
settings, refer to the Instruction
Manual of the inverter.
Solution
Check for the GOT type.
• Set the same communication
protocol for the inverter and the
GOT.
• Set a value other than "0" in Pr.122
PU communication check time
interval, Pr.336 RS-485
communication check time
interval, Pr.548 USB
communication check time
interval.
• Set a larger value for the timeout
setting of the software.
• Cable connection/replacement.
Check for communication cable and
power supply of devices.
After closing GX drawing software, try
communication again.
After closing GX drawing software, try
communication again.
Set lower baud rate and make a
communication.
Check for the baud rate supported by
connected devices.
• Set a larger value for the timeout
setting of the software.
• Cable connection/replacement.
Check for the connection.
• Set a larger value for the timeout
setting of the software.
• Monitor only the station which the
GOT is connected.
• Check that the GOT is operating
correctly and try again.
4. TROUBLE INDICATION
4.1 Error code
1
2
3
4
5
6
7
8
9
10
223