• The FR-E800-E or FR-E800-SCE inverter does not support some input signals. The unsupported signals cannot be set in
Pr.178 to Pr.184 (Input terminal function selection).
When the following input signals are used in the source inverter, set the corresponding parameters as required in the
"Parameter list" window because they are not converted.
JOG signal: JOG operation selection
OH signal: External thermal relay input
X10 signal: Inverter run enable signal (FR-XC/FR-HC2/FR-CV connection)
X12 signal: PU operation external interlock
X16 signal: PU-External operation switchover
STP (STOP) signal: Start self-holding selection
RES signal: Inverter reset
X65 signal: PU/NET operation switchover
X66 signal: External/NET operation switchover
X67 signal: Command source switchover
• When "60" is set in Pr.505 Speed setting reference in the FR-E800 inverter, the maximum value of the speed display is
almost one-half of that in the FR-E700 inverter. Depending on the setting in the FR-E700 inverter, an out-of-range error
(0x80010011) may occur for Pr.1, Pr.18, Pr.37, or Pr.505. If the error occurs, take the following corrective actions.
When the value set in Pr.1 or Pr.18 is too large, set a smaller value.
If the out-of-range error persists after the Pr.1 or Pr.18 setting is changed, check the Pr.37 setting.
 To convert from FR-B (A700) inverters to FR-B (A800) inverters
• Set the following parameters as required in the "Parameter list" window because they are not converted.
Pr.69 Retry count display erase
Pr.170 Watt-hour meter clear
Pr.171 Operation hour meter clear
Pr.172 to Pr.174 (User group selection)
Pr.259 Main circuit capacitor life measuring
Pr.498 PLC function flash memory clear
Pr.501 (Communication option parameter)
Pr.610 PID measured value input selection
Pr.503, Pr.686, and Pr.688 (Maintenance timer)
Pr.805 Torque command value (RAM)
Pr.898 Power saving cumulative monitor clear
Pr.991 PU contrast adjustment
Pr.1006 to Pr.1008 (Clock function)
Pr.1020 Trace operation selection
• It is recommended to adjust the setting of the following parameters again after conversion according to the mechanical
system because they are used for adjustment.
C2 (Pr.902) to C7 (Pr.905) (Frequency setting input calibration parameters)
• Since the communication-related parameters (Pr.117 to Pr.124, Pr.331 to Pr.337, Pr.341, Pr.547, and Pr.548) are also
converted, communication may be disabled depending on the setting after the setting is written to parameters. For
example, when Pr.122/Pr.336 RS-485 communication check time interval = "0 (initial value)", a communication error
(E.PUE, E.SER) occurs immediately after the operation mode with the command source is selected.
• If "63" is set in Pr.184 AU terminal function selection to enable the PTC thermal error detection (E.PTC) in the source
FR-B (A700) inverter, setting of Pr.561 and Pr.1016 and connecting the motor to the target FR-B (A800) inverter via
terminals 2 and 10 are required. For the parameter details and terminal connection, refer to the Instruction Manual of the
inverter.
130
3. FUNCTION
3.3 Convert