 Related parameter list
Availability, initial values, and setting ranges of parameters differ depending on the inverter. For details, refer to the Instruction
Manual of the relevant model.
• 800 series
Pr.
Name
117
PU communication station number
122
PU communication check time interval
123
PU communication waiting time setting 9999
331
RS-485 communication station number 0
N030
336
RS-485 communication check time
N036
interval
337
RS-485 communication waiting time
N037
setting
549
Protocol selection
N000
550
NET mode operation command source
D012
selection
*5
PU mode operation command source
551
selection
D013
*1
When "1" (MODBUS RTU protocol) is set in Pr.549, the setting range within parentheses is applied.
*2
When a value outside the setting range is set, the inverter operates at the initial value.
*3
Pr.549 = "0" (Mitsubishi inverter (Computer link) protocol).
*4
The setting is available only for the FR-F800 series.
*5
Pr. 551 is always write-enabled.
Initial
Setting range
value
Set the inverter station number.
0 to 31
0
Set the inverter station numbers when two or more
*1*2
(0 to 247)
inverters are connected to one personal computer.
RS-485 communication can be made. Note that a
communication fault (E.PUE) occurs as soon as the
0
drive unit is switched to the operation mode with
command source.
Communication check (signal loss detection) time
0
interval.
0.1 to 999.8 s
If a no-communication state persists for the
permissible time or longer, the inverter output is shut
off. (The operation depends on the Pr.502 setting.)
9999
No communication check (signal loss detection).
Set the waiting time between data transmission to the
0 to 150 ms
inverter and the response.
9999
Set with communication data.
Set the inverter station number.
0 to 31
Set the inverter station numbers when two or more
inverters are connected to one personal computer.
RS-485 communication is enabled. However, the
0
inverter output is shut off if operation is changed to
NET operation mode.
Set the interval of communication check (signal loss
0 s
detection) time. If a no-communication state persists
0.1 to 999.8 s
for the permissible time or longer, the inverter output is
shut off.
9999
No communication check (signal loss detection)
Set the waiting time between data transmission to the
0 to 150 ms
inverter and response.
9999
9999
Set with communication data.
Mitsubishi inverter protocol (computer link)
*3
0
0
1
MODBUS RTU protocol
*4
BACnet MS / TP protocol
2
The communication option is the command interface
0
enabled in the NET operation mode.
The RS-485 terminals are the command interface
1
enabled in the NET operation mode.
9999
Communication option is recognized automatically.
Basically, the RS-485 terminals are the command
9999
interface. When the communication option is installed,
the communication option is the command interface.
The RS-485 terminals are the command interface
1
enabled in the PU operation mode.
The PU connector is the command interface enabled
2
in the PU operation mode.
The USB connector is the command interface in the
9999
3
PU operation mode.
USB automatic recognition
Basically, the operation panel (PU connector) is the
9999
command interface. When the USB connector is used,
it is the command interface.
Description
1. OUTLINE
1.4 Connection and parameter setting
1
2