3.8.1

AI fault diagnosis details

 AI fault diagnosis result screen
A
D
Symbol
Name
A
Model
B
Fault name
C
Fault No.
D
Probability
E
Cause
F
Next fault (left arrow key)
Previous fault (right arrow
G
key)
H
Scroll bar (up/down key)
I
Page indicator
J
Help
K
Change parameters
 AI fault diagnosis result screen (cause selection)
Symbol
Name
A
Action
B
Details (space key)
F
J
K
Shows the model of the inverter of the selected station number.
Shows the name of fault.
Shows the fault record number.
Shows the probability (high, mid, and low) of each cause.
Shows probable causes of the fault.
When a cause is selected, details of corrective action to be taken and the [Details] button appear.
(Refer to
page
159.)
Shows probable causes of the subsequent fault. Not applicable when no subsequent fault exists.
Shows probable causes of the previous fault. Not applicable when no previous fault exists.
Used for scrolling up/down when there are many probable fault causes.
Shows the current page and the total number of pages.
Displays the help window.
Shows parameters changed after the startup. (Refer to
A
Corrective actions are suggested.
Shows a window for details of the parameters related to the cause. (Refer to
C
B
E
I
Function/description
page
Function/description
G
H
161.)
B
page
160.)
3. FUNCTION
3.8 AI fault diagnosis
1
2
3
4
5
6
7
8
9
10
159

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnd-frc2-e