Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 222

Table of Contents

Advertisement

Error code (HEX)
The time cannot be set if the
0x80020009
difference with the inverter time
is 10 years or more.
The specification of the
0x80030001
communication port is incorrect.
0x80030002
0x80030003
0x80030004
0x80030005
An unexpected error occurred in
0x80030006
S/W.
0x80030007
0x80030008
0x80030009
USB communication was
0x8003000A
interrupted.
The communication line cannot
0x8003000B
be opened.
Duplication was detected in
0x8003000C
station number of the USB
communication.
An unexpected error occurred in
0x8003000D
S/W.
The driver is not installed or
0x8003000E
broken.
0x8003000F
0x80030010
An unexpected error occurred in
0x80030011
S/W.
0x80030012
0x80030013
An unexpected error occurred in
0x9000C05C
S/W.
Error message
Real time clock setting error
The communication port is set
disabled.
Another application is already
using the port.
Please contact your sales representative.
Invalid USB communication
settings.
Incorrect USB type
Please contact your sales representative.
The driver is not installed or is
broken.
Please contact your sales representative.
• Electromagnetic interference
• Cable breakage/damage
Possible cause
Set appropriate time in Pr.1006 to
Pr.1008 of the inverter.
• Activate the port using Device
Manager.
• Close other applications, and
establish the online connection.
Check the system settings.
Reinstall the software.
• Try again.
• Check for cable connection.
• Replace any faulty cable.
Countermeasure
221
4. TROUBLE INDICATION
4.1 Error code
1
2
3
4
5
6
7
8
9
10