Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 227

Table of Contents

Advertisement

Error code (HEX)
*1
0xA001**16
*1
0xA002**16
*1
0xA001**17
*1
0xA002**17
*1
0xA001**18
*1
0xA002**18
*1
0xA001**20
*1
0xA002**20
*1
0xA001**21
*1
0xA002**21
*1
0xA00E**04
*1
0xA00F**04
*1
The value displayed in ** position depends on the applicable error.
226
4. TROUBLE INDICATION
4.1 Error code
Error message
Safety parameter settings are corrupt.
A safety parameter clearing error
occurred.
The password protection is still active.
A password writing error occurred.
A communication error occurred.
Countermeasure
• Retry the operation interrupted by the fault.
• Perform safety parameter clear.
If the problem still persists after taking the above measure, contact
your sales representative.
• Enter the correct password.
• If you forget the password, perform safety parameter clear to
reset the password to the initial value, then enter the password
again.
If the problem still persists after taking the above measure, contact
your sales representative.
• Retry the operation interrupted by the fault.
• Perform safety parameter clear.
If the problem still persists after taking the above measure, contact
your sales representative.