Displayed items
Item
No.
Model Name
Communication Method
Protocol
Fixed Buffer Send/Receive Setting
PLC
IP Address
Port No.
Sensor/Device
MAC Address
Host Name
IP Address
Port No.
Subnet Mask
Default Gateway
*1 Cannot be set in this product.
*2 In TCP/IP connection, the module can be connected up to the number calculated by the following formula: (the maximum number of
connections in the setting for external device configuration) - (the number of connections whose communication methods are not
"MELSOFT Connection") + 1. When a device is connected via multiple connection routes, it is counted as one device for each
connection route. For MELSOFT products on a personal computer, each connected MELSOFT product is counted as one device even if
they are connected via the same connection route. (When connecting CW Configurator which runs on this product, it is also counted as
one device.)
*3 In UDP/IP connection, there is no restriction on the number of connections. However, because simultaneous communication from
multiple connected devices can overload network, communication may not be established in such overloaded network conditions.
*4 Own station port numbers 1 to 1023 are numbers for reserved in general (WELL KNOWN PORT NUMBERS), and port numbers 61440
to 65534 are numbers used for other communication functions. Using the port number within the range of 1024 to 4999 or 5010 to 61439
is recommended.
13 MELSOFT CONNECTION FUNCTION
140
13.1 Connection Method
Description
A connection number to distinguish settings for each user connection.
The name of a target device is displayed.
Set the method for communication with a target device.
Select the communication protocol for a target device.
Not required.
Not required.
*1*4
Set the port number for each connection of Ethernet-equipped module.
Not required.
Not required.
*1
Set the IP address of a target device.
*1
Set the port number of a target device.
To send data to all the port numbers, set '65535.'
Not required.
Not required.
Setting range
The number is set in the following
range starting with 1.
1 to 16
*1
• Broadcast Send
*1
• Broadcast Receive
• Fixed Buffer (Procedure
*1
Exist)
*1
• Fixed Buffer (No Procedure)
*1
• Random Access Buffer
*1
• Predefined Protocol
*1
• Socket Communication
• MELSOFT Connection
*1
• SLMP
*2
• TCP
*3
• UDP
1 to 4999, 5010 to 65534
(Default: Blank)
0.0.0.1 to 223.255.255.254
(Default: Blank)
1 to 65534, 65535
(Default: Blank)