ERROR CLEAR FUNCTION
This function clears all the continuation errors in this product.
Precautions
• Since this function clears all the continuation errors at once, unintended errors may also get cleared.
• Errors cleared by this function are not removed from the event history.
• Any errors occurred in a module other than this product cannot be cleared by this function.
Using CW Configurator
Clear errors by performing the module diagnostics in CW Configurator. (CW Configurator Operating Manual)
Using a user program
Clear errors with a MELSEC data link function.
1.
Check the detected continuation errors with special registers (SD10 to SD25).
2.
Clear the cause of the continuation errors.
3.
Execute the CCPU_ClearError function.