Checking Errors in CW Configurator

Check an occurred error and error history, and identify the error cause by using CW Configurator. The detailed information
such as error causes and corrective actions obtained from CW Configurator is more helpful than those obtained visually.
CW Configurator has the following functions to support troubleshooting:
Function
System monitor
Module diagnostics
Event history
For details on each function of CW Configurator, refer to the following:
CW Configurator Operating Manual
Precautions
When the operation mode is other than the normal mode, errors cannot be checked in CW Configurator. (Page 26
Operation mode)
System monitor
The system monitor function displays the module configuration, detailed information of each module, and the error status.
[Diagnostics]  [System Monitor]
Precautions
• When this product is operating in other than normal mode, this product is displayed as a 0 point unidentified module with
the system monitor function of GX Works3 connected to another CPU module in a multiple CPU system.
• The IP address of this product is not displayed in "IP Address (Port1 IPv4)" and "IP Address (Port2 IPv4)" on the system
monitor. Check the address from the network setting of Windows.
32 TROUBLESHOOTING
224
32.3 Checking Errors in CW Configurator
Description
To display the module configuration, detailed information for each module, and the error status
To diagnose the operating status of each module (module information, existence of an error, or error logs, etc.)
To display the event information, such as errors occurred in each module, performed operations, and errors on the