OCR Type A230
(4) Maximum/Minimum
Displays the upper and lower limits for the numerical calculation result.
You can use the Serial command to set and refer to the maximum and minimum
values from an externally connected piece of equipment.
Refer to 16.10 Referencing and Changing the Maximum and Minimum Limits
for Numerical calculations for details.
(5) Programmes
Displays the set calculation programme.
A numerical calculation program can be up to 55 characters in length, and up to
12 items can be set.
Example: BW01 + 50 = 7 characters = 2 items
(6) Data Bit
Sets the data length for when you will output numerical calculation results using
parallel output.
(7) Start
Press A to capture a new image and perform an inspection, outputting parallel and
serial signals in accordance with I/O settings.
Note
In screens that display A: Start, external start signals can also be
accepted.
Inspection Results and Output