Download Print this page

Panasonic A230 User Manual page 297

Machine vision system

Advertisement

OCR Type A230
Inspection result output example
The output format of the results changes depending on the settings in item 43. (Serial
Output).
Inspection result example
JD01 = ON
JD02 = OFF
CA01 = 2513
CA02 = 325
CA03 = –15
CA04 = 98
Serial output setting example 1
Serial output setting example 2
Communications (Serial and Parallel)
16.4 Inspection Execution and Result Output Procedures
1,0,2513,325,−15,98
(If an error occurs with the numerical
calculation, an "e" is output.)
Example:1,0,2513,e,−15,98
1 0 2513 0325 −015 0098
CA01
JD02
JD01
(If an error occurs with the numerical
calculation, an "e" is output.)
Example: 1025130325
The zeros are replaced with spaces.
C
R
C
R
C
R
CA02
CA03
CA04
e0098
C
R
16 − 21