16.8
Template (Smart matching) Re−registration
16.8.4
Notes Regarding Execution Order for Re− registration
Setting position (Re−registration Area Display: No)
Procedure:
1.
Specify the template number for performing re−registration, and input template
re−registration input signal IN8.
2.
READY signal goes OFF, and re−registration is executed.
3.
When re−registration is complete, the READY signal goes on.
Setting position (Re−registration Area Display: Yes)
Procedure:
1.
Specify the template number for performing re−registration, and input template
re−registration input signal IN8.
2.
READY signal goes off, and the re−registration area is displayed.
3.
Input template re−registration input signal IN8 again.
4.
When re−registration is complete, the READY signal goes on.
Execution position (Re−registration Area Display: No)
Procedure:
1.
Specify the template number for performing re−registration, and input template
re−registration input signal IN8.
2.
READY signal goes off, and the specified smart matching checker is
executed.
3.
Re−registration is executed at the position detected in step 2.
4.
When re−registration is complete, the READY signal goes on.
Execution position (Re−registration Area Display: Yes)
Procedure:
1.
Specify the template number for performing re−registration, and input template
re−registration input signal IN8.
2.
READY signal goes off, and the specified smart matching checker is
executed.
3.
Re−registration is executed at the position detected in step 2.
4.
Input template re−registration input signal IN8 again.
5.
When re−registration is complete, the READY signal goes on.